RB545 Mouse Anti-Human CD235a (Glycophorin A)
RB545 Mouse Anti-Human CD235a (Glycophorin A)
Flow cytometric analysis of CD235a (Glycophorin A) expression on Human peripheral blood erythrocytes.  Human whole blood was stained with either BD Horizon™ RB545 Mouse IgG2b, κ Isotype Control (Cat. No. 569292; dashed line histogram) or BD Horizon™ RB545 Mouse Anti-Human CD235a (Glycophorin A) antibody (Cat. No. 569736/569764; solid line histogram). The fluorescence histogram showing CD235a (Glycophorin A) expression (or Ig Isotype control staining) was derived from gated events with the forward and side light-scatter characteristics of erythrocytes. Samples were acquired on the BD FACSymphony™ A5 SE Cell Analyzer and spectrally unmixed using FlowJo™ v10.8 software.
Flow cytometric analysis of CD235a (Glycophorin A) expression on Human peripheral blood erythrocytes.  Human whole blood was stained with either BD Horizon™ RB545 Mouse IgG2b, κ Isotype Control (Cat. No. 569292; dashed line histogram) or BD Horizon™ RB545 Mouse Anti-Human CD235a (Glycophorin A) antibody (Cat. No. 569736/569764; solid line histogram). The fluorescence histogram showing CD235a (Glycophorin A) expression (or Ig Isotype control staining) was derived from gated events with the forward and side light-scatter characteristics of erythrocytes. Samples were acquired on the BD FACSymphony™ A5 SE Cell Analyzer and spectrally unmixed using FlowJo™ v10.8 software.
Product Details
Down Arrow Up Arrow


BD Horizon™
CD235ab; CD235a, Glycophorin-A, GYPA, GPA; CD235b; Glycophorin-B, GYPB, GPB
Human (QC Testing)
Mouse IgG2b, κ
Flow cytometry (Routinely Tested)
5 µl/test
VII 70299
2993, 2994
Aqueous buffered solution containing ≤0.09% sodium azide.
RUO


Preparation And Storage

The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze. The antibody was conjugated to the dye under optimum conditions and unreacted dye was removed.

Recommended Assay Procedures

BD® CompBeads can be used as surrogates to assess fluorescence spillover (compensation). When fluorochrome conjugated antibodies are bound to BD® CompBeads, they have spectral properties very similar to cells. However, for some fluorochromes there can be small differences in spectral emissions compared to cells, resulting in spillover values that differ when compared to biological controls. It is strongly recommended that when using a reagent for the first time, users compare the spillover on cells and BD® CompBeads to ensure that BD® CompBeads are appropriate for your specific cellular application.

Product Notices

  1. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
  2. This reagent has been pre-diluted for use at the recommended Volume per Test. We typically use 1 × 10^6 cells in a 100-µl experimental sample (a test).
  3. An isotype control should be used at the same concentration as the antibody of interest.
  4. Please observe the following precautions: Absorption of visible light can significantly alter the energy transfer occurring in any tandem fluorochrome conjugate; therefore, we recommend that special precautions be taken (such as wrapping vials, tubes, or racks in aluminum foil) to prevent exposure of conjugated reagents, including cells stained with those reagents, to room illumination.
  5. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  6. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
  7. Human donor specific background has been observed in relation to the presence of anti-polyethylene glycol (PEG) antibodies, developed as a result of certain vaccines containing PEG, including some COVID-19 vaccines. We recommend use of BD Horizon Brilliant™ Stain Buffer in your experiments to help mitigate potential background. For more information visit https://www.bdbiosciences.com/en-us/support/product-notices.
  8. Please refer to http://regdocs.bd.com to access safety data sheets (SDS).
  9. For U.S. patents that may apply, see bd.com/patents.
569764 Rev. 1
Antibody Details
Down Arrow Up Arrow
GA-R2 (HIR2)

The GA-R2 (also known as HIR2) monoclonal antibody specifically binds to CD235a and CD235b. CD235a is also known as Glycophorin A (GYPA, GPA, GLPA), Sialoglycoprotein alpha, MN sialoglycoprotein, or PAS-2. CD235b is otherwise known as Glycophorin B (GYPB, GPB, GLPB), Sialoglycoprotein delta, SS-active sialoglycoprotein, or PAS-3. CD235a and CD235b are type I transmembrane sialoglycoproteins that are expressed on human erythrocytes, erythroid precursor cells and certain leukemic cell types. CD235a carries blood group M and N antigens, whereas CD235b contains S, s, and U antigens. This antibody is useful for the identification and characterization of erythrocytes, certain myeloid leukemic cell types, and studies of erythroid cell development and infectious diseases with erythrocyte involvement. Glycophorins may play a role in preventing cell agglutination.

569764 Rev. 1
Format Details
Down Arrow Up Arrow
RB545
The BD Horizon RealBlue™ 545 (RB545) fluorochrome is part of the BD family of blue (488-nm) laser dyes. It is a small organic fluorochrome with an excitation maximum (Ex Max) at 496-nm and an emission maximum (Em Max) at 545-nm. Driven by BD innovation, RB545 can be used on spectral cytometers and is designed to be excited by the blue (488-nm) laser with minimal excitation by the 561-nm yellow-green laser. RB545 has minimal spillover into yellow-green detectors and a brightness level similar to FITC.  Given its unique emission max, on a spectral instrument RB545 can be used simultaneously with FITC and PE to provide an additional color off of the blue laser. Please ensure that your instrument configuration (lasers and optical filters) is appropriate for this dye.
altImg
RB545
Blue 488 nm
496 nm
545 nm
569764 Rev.1
Citations & References
Down Arrow Up Arrow
View product citations for antibody "569764" on CiteAb

Development References (7)

  1. Bain BJ. Leukemia diagnosis: A guide to the FAB classification. 1990.
  2. Blanchard D, Roux YP-L, Vusio P, Follea G. Characterization of monoclonal antibodies directed to human red blood cell glycophorins A and B. In: Mason D. David Mason .. et al., ed. Leucocyte typing VII : white cell differentiation antigens : proceedings of the Seventh International Workshop and Conference held in Harrogate, United Kingdom. Oxford: Oxford University Press; 2002:579-582.
  3. Gross S, Helm K, Gruntmeir JJ, Stillman WS, Pyatt DW, Irons RD. Characterization and phenotypic analysis of differentiating CD34+ human bone marrow cells in liquid culture. Br J Haematol. 1997; 5(318):326. (Clone-specific: Flow cytometry). View Reference
  4. Keren DF, Hanson CA, Hurtubise PE. David F. Keren, Curtis A. Hanson, Paul E. Hurtubise., ed. Flow cytometry and clinical diagnosis. Chicago: ASCP Press; 1994:1-676.
  5. Loken MR, Civin CI, Bigbee WL, Langlois RG, Jensen RH. Coordinate glycosylation and cell surface expression of glycophorin A during normal human erythropoiesis. Blood. 1987; 70(6):1959-1961. (Biology). View Reference
  6. Nakahata T, Okumura N. Cell surface antigen expression in human erythroid progenitors: erythroid and megakaryocytic markers. Leuk Lymphoma. 1994; 13(5-6):401-409. (Biology). View Reference
  7. Rogers CE, Bradley MS, Palsson BO, Koller MR. Flow cytometric analysis of human bone marrow perfusion cultures: erythroid development and relationship with burst-forming units-erythroid. Exp Hematol. 1996; 24(5):597-604. (Biology). View Reference
View All (7) View Less
569764 Rev. 1

 

Please refer to Support Documents for Quality Certificates


Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described


Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.