BV480 Mouse Anti-Human CD20
Clone 2H7 (RUO)
- Brand BD Horizon™
- Alternative Name MS4A1; B1; Bp35; LEU-16; S7
- Vol. Per Test 5 µl
- Isotype Mouse C57BL/6 IgG2b, κ
- Reactivity Human (QC Testing) Rhesus, Cynomolgus, Baboon (Tested in Development)
- Application
Flow cytometry (Routinely Tested)
- Immunogen Human 6.16c1.3 B cell line
- Workshop No. II B22; III B739, NL382; IV B201
- Entrez Gene ID 931
- Storage Buffer Aqueous buffered solution containing BSA and ≤0.09% sodium azide.
- Regulatory Status RUO
Regulatory Status Legend
Description
The 2H7 monoclonal antibody specifically binds to CD20, encoded by the MS4A1 (Membrane-spanning 4-domains, subfamily A, member 1) gene. CD20 is a 33-37 kDa, unglycosylated four-transmembrane phosphoprotein. CD20 is expressed on pre-B-cells, resting and activated B cells, and follicular dendritic cells, but not plasma cells. Low level CD20 expression is observed on a small subset of normal circulating T lymphocytes. The CD20 molecule is involved in the regulation of B-cell activation.
The antibody was conjugated to BD Horizon BV480 which is part of the BD Horizon Brilliant™ Violet family of dyes. With an Ex Max of 436-nm and Em Max at 478-nm, BD Horizon BV480 can be excited by the violet laser and detected in the BD Horizon BV510 (525/40-nm) filter set. BV480 has less spillover into the BV605 detector and, in general, is brighter than BV510.
FORMATO
BD Horizon™ BV480 is part of the BD Horizon Brilliant™ Violet family of dyes. With an Ex Max of 436-nm and Em Max at 478-nm, BD Horizon BV480 can be excited by the violet laser and detected in the BD Horizon™ BV510 (525/40-nm) filter set. BV480 has less spillover into the BD Horizon™ BV605 detector and, in general, is brighter than BD Horizon BV510. Due to similar excitation and emission properties, BV480, BV510 and V500 cannot be used simultaneously.
Suggested Companion Products
BV480 Mouse IgG2b, κ Isotype Control RUO
50 µg
Cat No: 566080
BV480 Mouse Anti-Human CD20 2H7 RUO
25 Tests
Cat No: 566181
APC Mouse Anti-Human CD19 HIB19 RUO
100 Tests
Cat No: 555415
APC Mouse Anti-Human CD19 HIB19 RUO
25 Tests
Cat No: 561742
Brilliant Stain Buffer RUO
100 Tests
Cat No: 563794
Lysing Solution 10X Concentrate IVD
100
Cat No: 349202
Lysing Buffer RUO
100 mL
Cat No: 555899
Stain Buffer (FBS) RUO
500 mL
Cat No: 554656
Stain Buffer (BSA) RUO
500 mL
Cat No: 554657
RECURSOS E FERRAMENTAS | ||||||
---|---|---|---|---|---|---|
Spectrum Viewer | Panel Designer | Spectrum Viewer | Regulatory Document Website |
Preparation and Storage
Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze.
The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography.
The antibody was conjugated with BD Horizon BV480 under optimum conditions, and unconjugated antibody and free BD Horizon BV480 were removed.
Product Notices
- This reagent has been pre-diluted for use at the recommended Volume per Test. We typically use 1 × 10^6 cells in a 100-µl experimental sample (a test).
- An isotype control should be used at the same concentration as the antibody of interest.
- Source of all serum proteins is from USDA inspected abattoirs located in the United States.
- Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
- Species testing during development may have been performed with a different format of the same clone. Selected applications have been tested for cross-reactivity.
- BD Horizon Brilliant Violet 480 is covered by one or more of the following US patents: 8,575,303; 8,354,239.
- For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
- Please refer to www.bdbiosciences.com/pharmingen/protocols for technical protocols.
For optimal and reproducible results, BD Horizon Brilliant Stain Buffer should be used anytime two or more BD Horizon Brilliant dyes are used in the same experiment. Fluorescent dye interactions may cause staining artifacts which may affect data interpretation. The BD Horizon Brilliant Stain Buffer was designed to minimize these interactions. More information can be found in the Technical Data Sheet of the BD Horizon Brilliant Stain Buffer (Cat. No. 563794).