BV750 Rat Anti-Human IL-2
BV750 Rat Anti-Human IL-2
Two color flow cytometric analysis of IL-2 expression in activated human peripheral blood lymphocytes. Human peripheral blood mononuclear cells were stimulated for 5 h with Phorbol 12-Myristate 13-Acetate (PMA, Sigma P-8139; 50 ng/ml) and Calcium Ionophore A23187 (Sigma C-9275; 1 μg/ml), in the presence of BD GolgiStop™ Protein Transport Inhibitor (containing Monensin) (Cat. No. 554724). The cells were harvested, washed with BD Pharmingen™ Stain Buffer (FBS) (Cat. No. 554656), and fixed with BD Cytofix™ Fixation Buffer (Cat. No. 554655). The cells were then washed and stained in BD Perm/Wash™ Buffer (Cat. No. 554723) with APC Mouse Anti-Human CD3 antibody (Cat No. 555335/561810/561811) and either BD Horizon™ BV750 Rat IgG2a, κ Isotype Control (Cat No. 566362; Left Plot) or BD Horizon BV750 Rat Anti-Human IL-2 antibody (Cat No. 566361; Right Plot) at 0.5 μg/test using BD Biosciences Intracellular Cytokine Staining Protocol. The two-color flow cytometric contour plots showing the correlated expression of IL-2 (or Ig Isotype control staining) versus CD3 were derived from gated events with the forward and side light-scatter characteristics of intact lymphocytes. Flow cytometric analysis was performed using a BD LSRFortessa™ X-20 Cell Analyzer System. Data shown on this Technical Data Sheet are not lot specific.
Two color flow cytometric analysis of IL-2 expression in activated human peripheral blood lymphocytes. Human peripheral blood mononuclear cells were stimulated for 5 h with Phorbol 12-Myristate 13-Acetate (PMA, Sigma P-8139; 50 ng/ml) and Calcium Ionophore A23187 (Sigma C-9275; 1 μg/ml), in the presence of BD GolgiStop™ Protein Transport Inhibitor (containing Monensin) (Cat. No. 554724). The cells were harvested, washed with BD Pharmingen™ Stain Buffer (FBS) (Cat. No. 554656), and fixed with BD Cytofix™ Fixation Buffer (Cat. No. 554655). The cells were then washed and stained in BD Perm/Wash™ Buffer (Cat. No. 554723) with APC Mouse Anti-Human CD3 antibody (Cat No. 555335/561810/561811) and either BD Horizon™ BV750 Rat IgG2a, κ Isotype Control (Cat No. 566362; Left Plot) or BD Horizon BV750 Rat Anti-Human IL-2 antibody (Cat No. 566361; Right Plot) at 0.5 μg/test using BD Biosciences Intracellular Cytokine Staining Protocol. The two-color flow cytometric contour plots showing the correlated expression of IL-2 (or Ig Isotype control staining) versus CD3 were derived from gated events with the forward and side light-scatter characteristics of intact lymphocytes. Flow cytometric analysis was performed using a BD LSRFortessa™ X-20 Cell Analyzer System. Data shown on this Technical Data Sheet are not lot specific.
Product Details
Down Arrow Up Arrow


BD Horizon™
IL2; Interleukin-2; T-cell growth factor; TCGF
Human (QC Testing), Rhesus, Cynomolgus, Baboon (Tested in Development)
Rat IgG2a, κ
Human IL-2 Recombinant Protein
Intracellular staining (flow cytometry) (Routinely Tested)
0.2 mg/ml
3558
AB_2739710
Aqueous buffered solution containing ≤0.09% sodium azide.
RUO


Preparation And Storage

Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze. The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated with BD Horizon BV750 under optimum conditions, and unconjugated antibody and free BD Horizon BV750 were removed.

Recommended Assay Procedures

For optimal and reproducible results, BD Horizon Brilliant Stain Buffer should be used anytime two or more BD Horizon Brilliant dyes are used in the same experiment. Fluorescent dye interactions may cause staining artifacts which may affect data interpretation. The BD Horizon Brilliant Stain Buffer was designed to minimize these interactions. More information can be found in the Technical Data Sheet of the BD Horizon Brilliant Stain Buffer (Cat. No. 563794/566349).

Product Notices

  1. Since applications vary, each investigator should titrate the reagent to obtain optimal results.
  2. An isotype control should be used at the same concentration as the antibody of interest.
  3. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  4. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
  5. BD Horizon Brilliant Stain Buffer is covered by one or more of the following US patents: 8,110,673; 8,158,444; 8,575,303; 8,354,239.
  6. BD Horizon Brilliant™ Violet 750 is covered by one or more of the following US patents: 8,158,444; 8,802,450; 8,575,303; 8,455,613; 8,227,187; 8,841,072; 8,110,673.
  7. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
566361 Rev. 1
Antibody Details
Down Arrow Up Arrow
MQ1-17H12

The MQ1-17H12 monoclonal antibody specifically binds to the multifunctional cytokine, human Interleukin-2 (IL-2). IL-2 is produced by activated T cells and has multiple functions that can affect the growth, proliferation, differentiation and survival of many different target cell types including T cells, B cells, NK cells, monocytes and macrophages. The immunogen used to generate the MQ1-17H12 hybridoma was purified recombinant human IL-2 protein. The MQ1-17H12 antibody reportedly neutralizes the biological activity of human IL-2.

The antibody was conjugated to BD Horizon BV750 which is part of the BD Horizon Brilliant™ Violet family of dyes. This dye is a tandem fluorochrome of BD Horizon BV421 with an Ex Max of 405-nm and an acceptor dye with an Em Max at 750-nm. BD Horizon Brilliant BV750 can be excited by the violet laser (405 nm) and detected with a 750/30 nm filter with a 740 nm long pass. Due to spectral differences between labeled cells and beads, using BD™ CompBeads can result in incorrect spillover values when used with BD Horizon BV750 reagents. Therefore, the use of BD CompBeads or BD CompBeads Plus to determine spillover values for these reagents is not recommended.

566361 Rev. 1
Format Details
Down Arrow Up Arrow
BV750
The BD Horizon Brilliant Violet™ 750 (BV750) dye is part of the BD Horizon Brilliant Violet™ family of dyes. This tandem fluorochrome is comprised of a BV421 donor with an excitation maximum (Ex Max) of 409-nm and an acceptor dye with an emission maximum (Em Max) at 754-nm. BV750, driven by BD innovation, is designed to be excited by the violet laser (405-nm) and detected using an optical filter centered near 750-nm (e.g., a 750/30 nm bandpass filter). Please ensure that your instrument’s configurations (lasers and optical filters) are appropriate for this dye.
altImg
BV750
Violet 405 nm
409 nm
754 nm
566361 Rev.1
Citations & References
Down Arrow Up Arrow

Development References (4)

  1. Abrams J. Immunoenzymetric assay of mouse and human cytokines using NIP-labeled anti-cytokine antibodies. Curr Protoc Immunol. 2001; 1:6.20-6.21. (Clone-specific: ELISA). View Reference
  2. Abrams JS, Roncarolo MG, Yssel H, Andersson U, Gleich GJ, Silver JE. Strategies of anti-cytokine monoclonal antibody development: immunoassay of IL-10 and IL-5 in clinical samples. Immunol Rev. 1992; 127:5-24. (Clone-specific: Blocking, ELISA, Immunoprecipitation). View Reference
  3. Mascher B, Schlenke P, Seyfarth M. Expression and kinetics of cytokines determined by intracellular staining using flow cytometry. J Immunol Methods. 1999; 223(1):115-121. (Clone-specific: Flow cytometry). View Reference
  4. Prussin C, Metcalfe DD. Detection of intracytoplasmic cytokine using flow cytometry and directly conjugated anti-cytokine antibodies. J Immunol Methods. 1995; 188(1):117-128. (Methodology: Flow cytometry). View Reference
View All (4) View Less
566361 Rev. 1

Please refer to Support Documents for Quality Certificates


Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described


Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.