Skip to main content Skip to navigation
Alexa Fluor® 488 Mouse Anti-Human CD19
Alexa Fluor® 488 Mouse Anti-Human CD19
Immunohistofluorescent analysis of CD19 expression by cells within human tonsil (left panel). A human tonsil cryosection (5 µm) was fixed with BD Cytofix™ Fixation Buffer (Cat. No. 554655), blocked with 5% goat serum and 1% BSA diluted in 1x PBS, and stained with BD Pharmingen™ Purified Mouse Anti-Human CD11c antibody (Cat. No. 565805) followed by BD Horizon™ BV480 Goat Anti-Mouse Ig second step antibody (Cat. No. 564877, pseudo-colored green). Sections were thoroughly washed, then stained with Alexa Fluor® 488 Mouse Anti-Human CD19 antibody (Cat. No. 557697, pseudo-colored blue) and BD Horizon™ BV421 Mouse Anti-Human CD3 antibody (Cat. No. 562426/562427, pseudo-colored red). Images were captured on a standard epifluorescence microscope. Original magnification, 20x. Profile of peripheral blood lymphocytes analyzed by flow cytometry (right panel).
Immunohistofluorescent analysis of CD19 expression by cells within human tonsil (left panel). A human tonsil cryosection (5 µm) was fixed with BD Cytofix™ Fixation Buffer (Cat. No. 554655), blocked with 5% goat serum and 1% BSA diluted in 1x PBS, and stained with BD Pharmingen™ Purified Mouse Anti-Human CD11c antibody (Cat. No. 565805) followed by BD Horizon™ BV480 Goat Anti-Mouse Ig second step antibody (Cat. No. 564877, pseudo-colored green). Sections were thoroughly washed, then stained with Alexa Fluor® 488 Mouse Anti-Human CD19 antibody (Cat. No. 557697, pseudo-colored blue) and BD Horizon™ BV421 Mouse Anti-Human CD3 antibody (Cat. No. 562426/562427, pseudo-colored red). Images were captured on a standard epifluorescence microscope. Original magnification, 20x. Profile of peripheral blood lymphocytes analyzed by flow cytometry (right panel).
Product Details
Down Arrow Up Arrow


BD Pharmingen™
Human (QC Testing)
Mouse IgG1, κ
Flow cytometry (Routinely Tested), Immunofluorescence (Tested During Development)
5 µl
V CD19.11
930
AB_396806
Aqueous buffered solution containing BSA and ≤0.09% sodium azide.
RUO


Preparation And Storage

Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze. The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated to the dye under optimum conditions and unreacted dye was removed.

Recommended Assay Procedures

BD™ CompBeads can be used as surrogates to assess fluorescence spillover (Compensation).  When fluorochrome conjugated antibodies are bound to CompBeads, they have spectral properties very similar to cells.   However, for some fluorochromes there can be small differences in spectral emissions compared to cells, resulting in spillover values that differ when compared to biological controls.  It is strongly recommended that when using a reagent for the first time, users compare the spillover on cells and CompBead to ensure that BD Comp beads are appropriate for your specific cellular application.

Product Notices

  1. This reagent has been pre-diluted for use at the recommended Volume per Test. We typically use 1 × 10^6 cells in a 100-µl experimental sample (a test).
  2. An isotype control should be used at the same concentration as the antibody of interest.
  3. Source of all serum proteins is from USDA inspected abattoirs located in the United States.
  4. Alexa Fluor® 488 fluorochrome emission is collected at the same instrument settings as for fluorescein isothiocyanate (FITC).
  5. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  6. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
  7. This product is provided under an intellectual property license between Life Technologies Corporation and BD Businesses. The purchase of this product conveys to the buyer the non-transferable right to use the purchased amount of the product and components of the product in research conducted by the buyer (whether the buyer is an academic or for-profit entity). The buyer cannot sell or otherwise transfer (a) this product (b) its components or (c) materials made using this product or its components to a third party or otherwise use this product or its components or materials made using this product or its components for Commercial Purposes. Commercial Purposes means any activity by a party for consideration and may include, but is not limited to: (1) use of the product or its components in manufacturing; (2) use of the product or its components to provide a service, information, or data; (3) use of the product or its components for therapeutic, diagnostic or prophylactic purposes; or (4) resale of the product or its components, whether or not such product or its components are resold for use in research. For information on purchasing a license to this product for any other use, contact Life Technologies Corporation, Cell Analysis Business Unit Business Development, 29851 Willow Creek Road, Eugene, OR 97402, USA, Tel: (541) 465-8300. Fax: (541) 335-0504.
  8. Please refer to http://regdocs.bd.com to access safety data sheets (SDS).
  9. Alexa Fluor™ is a trademark of Life Technologies Corporation.
  10. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
557697 Rev. 6
Antibody Details
Down Arrow Up Arrow
HIB19

The HIB19 monoclonal antibody specifically binds to the 95 kDa type I transmembrane CD19 glycoprotein. CD19 is expressed during all stages of B-cell maturation and differentiation, except on plasma cells. CD19 is also present on follicular dendritic cells. It is not found on T cells or on normal granulocytes. CD19 is a signal transduction molecule that regulates B cell development, activation, proliferation and differentiation. It associates with the complement receptor 2 (CD21), TAPA-1 (CD81), Leu 13, and/or MHC class II to form a signal transduction complex on the surface of B cells. Anti-CD19 clone HIB19 partially blocks the binding of clone B43, another CD19-specific monoclonal antibody.

557697 Rev. 6
Format Details
Down Arrow Up Arrow
Alexa Fluor™ 488
Alexa Fluor™ 488 Dye is part of the BD blue family of dyes. This is a small organic fluorochrome with an excitation maximum (Ex Max) at 494-nm and an emission maximum (Em Max) at 517-nm. Alexa Fluor™ 488 is designed to be excited by the Blue laser (488 nm) and detected using an optical filter centered near 520-nm (e.g., a 530/30-nm bandpass filter). Please ensure that your instrument’s configurations (lasers and optical filters) are appropriate for this dye.
Alexa Fluor™ 488
Blue 488 nm
494 nm
517 nm
557697 Rev.6
Citations & References
Down Arrow Up Arrow

Development References (6)

  1. Bradbury LE, Goldmacher VS, Tedder TF. The CD19 signal transduction complex of B lymphocytes. Deletion of the CD19 cytoplasmic domain alters signal transduction but not complex formation with TAPA-1 and Leu 13. J Immunol. 1993; 151(6):2915-2927. (Biology). View Reference
  2. Favaloro EJ, Moraitis N, Koutts J, Exner T, Bradstock KF. Endothelial cells and normal circulating haemopoietic cells share a number of surface antigens. Thromb Haemost. 1989; 61(2):217-224. (Biology). View Reference
  3. Knapp W. W. Knapp .. et al., ed. Leucocyte typing IV : white cell differentiation antigens. Oxford New York: Oxford University Press; 1989:1-1182.
  4. Nadler LM, Anderson KC, Marti G, et al. B4, a human B lymphocyte-associated antigen expressed on normal, mitogen-activated, and malignant B lymphocytes. J Immunol. 1983; 131(1):244-250. (Biology). View Reference
  5. Schlossman SF. Stuart F. Schlossman .. et al., ed. Leucocyte typing V : white cell differentiation antigens : proceedings of the fifth international workshop and conference held in Boston, USA, 3-7 November, 1993. Oxford: Oxford University Press; 1995.
  6. Uckun FM, Muraguchi A, Ledbetter JA, et al. Biphenotypic leukemic lymphocyte precursors in CD2+CD19+ acute lymphoblastic leukemia and their putative normal counterparts in human fetal hematopoietic tissues. Blood. 1989; 73(4):1000-1015. (Biology). View Reference
View All (6) View Less
557697 Rev. 6

Please refer to Support Documents for Quality Certificates


Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described


Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.