Human C5a ELISA Kit II

BD OptEIA™ Human C5a ELISA Kit II

(RUO)
Product Details
Down Arrow Up Arrow


BD OptEIA™
Human (QC Testing)
ELISA (Routinely Tested)
RUO
AB_2869112


Preparation And Storage

Store unopened reagents at 2-8°C. do not use reagents after expiration date, or if turbidity is evident. Before use, bring all reagents to room temperature (18-25°C). Immediately after use, return to proper storage conditions. Lyophilized standards are stable until expiration date. After reconstitution, immediately aliquot standard stock in polypropylene vials at 50 µl per vial anf freeze at -80°C for up to 6 months. If necessary, store at 2-8°C for up to 8 hours prior to aliquotting/freezing. Do not leave reconstituted standard at room temperature.
557965 Rev. 1
Components
Down Arrow Up Arrow
Description Quantity/Size Part Number EntrezGene ID
Human C5a Standard 1 Plate(s) (3 ea) 51-9004473 727
557965 Rev. 1
Citations & References
Down Arrow Up Arrow

Development References (5)

  1. Bokisch, VA, and HJ Muller-Eberhard. Anaphylatoxin inactivator of human plasma: Its isolation and characterization as a carboxypeptidase. J Clin Invest. 1970; 49:2427-36. (Biology).
  2. Ember JA., Jagels MA., Hugli TE. Characterization of complement anaphylatoxins and their biological responses. In: J.E. Volanakis and M.M. Frank, ed. The human complement system in health and disease. Marcel Dekker, Inc; 1998:241-284.
  3. Hugli, TE, and HJ Muller-Eberhard. Anaphylatoxins: C3a and C3a. Advances in Immunology. 1978; 26:1-53. (Biology).
  4. Matsushita, M and T Fujita. Activation of the classical complement pathway by mannose-binding protein in association with a novel C1s-like serine protease. J Exp Med. 1992; 176:1497-1502. (Biology).
  5. Pfeifer PH, Kawahara MS, Hugli TE. Possible mechanism for in vitro complement activation in blood and plasma samples: futhan/EDTA controls in vitro complement activation. Clin Chem. 1999; 45(8):1190-1199. (Biology). View Reference
557965 Rev. 1

Please refer to Support Documents for Quality Certificates