Alexa Fluor® 700 Mouse Anti-Human CD86
Alert icon
Consider BD Horizon™ Red 718 Reagents, bright small molecule alternative to BD Pharmingen™ Alexa Fluor™ 700 with low background. More Info #
Alexa Fluor® 700 Mouse Anti-Human CD86
Flow cytometric analysis of CD86 on Daudi cells. Human Daudi cells were stained with either Alexa Fluor® 700 Mouse Anti-Human CD86 antibody (Cat. No. 561124; solid line histogram) or with a Alexa Fluor® 700 Mouse IgG1, κ Isotype Control (Cat. No. 557882; dashed line histogram). The fluorescence histograms were derived from gated events with the forward and side light-scatter characteristics of viable cells. Flow cytometry was performed on a BD LSR™ II Flow Cytometry System.
Flow cytometric analysis of CD86 on Daudi cells. Human Daudi cells were stained with either Alexa Fluor® 700 Mouse Anti-Human CD86 antibody (Cat. No. 561124; solid line histogram) or with a Alexa Fluor® 700 Mouse IgG1, κ Isotype Control (Cat. No. 557882; dashed line histogram). The fluorescence histograms were derived from gated events with the forward and side light-scatter characteristics of viable cells. Flow cytometry was performed on a BD LSR™ II Flow Cytometry System.
Product Details
Down Arrow Up Arrow


BD Pharmingen™
B7.2; B7-2; B-lymphocyte activation antigen B7-2; B70; BU63; CD28LG2; LAB72
Human (QC Testing), Rhesus, Cynomolgus, Baboon (Tested in Development)
Mouse BALB/c IgG1, κ
Human HBL-1 Cell Line
Flow cytometry (Routinely Tested)
5 µl
V B046, BP126
942
AB_10564087
Aqueous buffered solution containing protein stabilizer and ≤0.09% sodium azide.
RUO


Preparation And Storage

Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze. The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated to Alexa Fluor® 700 under optimum conditions, and unreacted Alexa Fluor® 700 was removed.

Product Notices

  1. This reagent has been pre-diluted for use at the recommended Volume per Test. We typically use 1 × 10^6 cells in a 100-µl experimental sample (a test).
  2. An isotype control should be used at the same concentration as the antibody of interest.
  3. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  4. Alexa Fluor® 700 has an adsorption maximum of ~700nm and a peak fluorescence emission of ~720nm. Before staining cells with this reagent, please confirm that your flow cytometer is capable of exciting the fluorochrome and discriminating the resulting fluorescence.
  5. Alexa Fluor® is a registered trademark of Molecular Probes, Inc., Eugene, OR.
  6. The Alexa Fluor®, Pacific Blue™, and Cascade Blue® dye antibody conjugates in this product are sold under license from Molecular Probes, Inc. for research use only, excluding use in combination with microarrays, or as analyte specific reagents. The Alexa Fluor® dyes (except for Alexa Fluor® 430), Pacific Blue™ dye, and Cascade Blue® dye are covered by pending and issued patents.
  7. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
  8. Species cross-reactivity detected in product development may not have been confirmed on every format and/or application.
  9. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
561124 Rev. 2
Antibody Details
Down Arrow Up Arrow
2331 (FUN-1)

The 2331 (FUN-1) monoclonal antibody specifically recognizes a 75 kDa transmembrane cell surface protein, CD86 (B70/B7-2), expressed primarily on monocytes, dendritic cells and activated B cells. Competitive binding assays demonstrate that, while both 2331 (FUN-1) and IT2.2 (Anti-CD86) antibodies specifically recognize the same molecule, they react with different epitopes. CD86 is a ligand for CD28 and CTLA-4 and plays an important role in costimulation of T cells in primary immune response. The 2331 (FUN-1) antibody blocks the costimulatory activity of CD86 when tested in functional studies.

561124 Rev. 2
Format Details
Down Arrow Up Arrow
Alexa Fluor™ 700
Alexa Fluor™ 700 dye is part of the BD red family of dyes. This is a small organic fluorochrome with an excitation maximum (Ex Max) at 697 nm and an emission maximum (Em Max) at 719-nm. Alexa Fluor™ 700 is designed to be excited by the Red (627–640-nm) laser and detected using an optical filter centered near 720-nm (e.g., a 720/40-nm bandpass filter). Please ensure that your instrument’s configurations (lasers and optical filters) are appropriate for this dye.
Alexa Fluor™ 700
Red 627-640 nm
697 nm
719 nm
561124 Rev.2
Citations & References
Down Arrow Up Arrow

Development References (5)

  1. Azuma H, Uno Y, Shigekiyo T, Saito S. Congenital plasminogen deficiency caused by a Ser572 to Pro mutation. Blood. 1993; 82(2):475-480. (Biology). View Reference
  2. Engel P, Gribben JG, Freeman GJ, et al. The B7-2 (B70) costimulatory molecule expressed by monocytes and activated B lymphocytes is the CD86 differentiation antigen. Blood. 1994; 84(5):1402-1407. (Biology). View Reference
  3. Engel P, Wagner N, Tedder TF. CD86 Workshop Report. In: Schlossman SF. Stuart F. Schlossman .. et al., ed. Leucocyte typing V : white cell differentiation antigens : proceedings of the fifth international workshop and conference held in Boston, USA, 3-7 November, 1993. Oxford: Oxford University Press; 1995:703-705.
  4. Nozawa Y, Wachi E, Tominaga K, Abe M, Wakasa H. A novel monoclonal antibody (FUN-1) identifies an activation antigen in cells of the B-cell lineage and Reed-Sternberg cells. J Pathol. 1993; 169(3):309-315. (Clone-specific). View Reference
  5. Yang XF, Chen Z, Wormsley SB. Nashville: American Society of Hematology; 1994.
View All (5) View Less
561124 Rev. 2

Please refer to Support Documents for Quality Certificates


Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described


Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.