Skip to main content Skip to navigation
Mouse IgG1 PE-Cy™7
Product Details
Down Arrow Up Arrow


BD™
IgG1, kappa Isotype Control (Anti-KLH)
Mouse BALB/c IgG1, κ
Keyhole limpet hemocyanin (KLH)
Flow cytometry
50 µg/mL
5 μL
Phosphate buffered saline with gelatin and 0.1% sodium azide.
ASR


Preparation And Storage

Store vials at 2°C–8°C. Conjugated forms should not be frozen. Protect from exposure to light. Each reagent is stable until the expiration date shown on the bottle label when stored as directed.

348798 Rev. 1
Antibody Details
Down Arrow Up Arrow
X40

The Mouse IgG1 antibody, clone X40, is derived from the hybridization of Sp2/0-Ag 14 mouse myeloma cells with spleen cells from BALB/c mice immunized with KLH.

The antibodies react specifically with keyhole limpet hemocyanin (KLH), an antigen not expressed on human cells or human cell lines.

348798 Rev. 1
Format Details
Down Arrow Up Arrow
PE-Cy7
PE-Cy7 dye is a part of the BD PE family of dyes. This tandem fluorochrome is comprised of a R-Phycoerythrin (PE) donor that has excitation maxima (Ex Max) of 496-nm and 566-nm and an acceptor dye, Cy™7, with an emission maximum (Em Max) at 781-nm. PE can be excited by the Blue (488-nm), Green (532-nm) and yellow-green (561-nm) lasers and detected using an optical filter centered near 781 nm (e.g., a 760/60-nm bandpass filter). The donor dye can be excited by the Blue (488-nm), Green (532-nm) and yellow-green (561-nm) lasers and the acceptor dye can be excited by the Red (627–640-nm) laser resulting in cross-laser excitation and fluorescence spillover. Please ensure that your instrument’s configurations (lasers and optical filters) are appropriate for this dye.
altImg
PE-Cy7
Yellow-Green 488 nm, 532 nm, 561 nm
496 nm, 566 nm
781 nm
348798 Rev.1
Citations & References
Down Arrow Up Arrow

Development References (2)

  1. Centers for Disease Control. Update: universal precautions for prevention of transmission of human immunodeficiency virus, hepatitis B virus, and other bloodborne pathogens in healthcare settings. MMWR. 1988; 37:377-388. (Biology).
  2. Clinical and Laboratory Standards Institute. 2005. (Biology).
348798 Rev. 1

Please refer to Support Documents for Quality Certificates


Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described


Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

Analyte Specific Reagent. Analytical and performance characteristics are not established.