Skip to main content Skip to navigation
BUV661 Rat Anti-Mouse CD354 (TREM-1)
Product Details
Down Arrow Up Arrow


BD OptiBuild™
CD354; TREM-1; Trem1
Mouse (Tested in Development)
Rat IgG2a, κ
Mouse TREM-1 (Ala21-Ser202) Recombinant Protein
Flow cytometry (Qualified)
0.2 mg/ml
AB_2874320
Aqueous buffered solution containing ≤0.09% sodium azide.
RUO


Preparation And Storage

Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze. The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated with BD Horizon BUV661 under optimal conditions that minimize unconjugated dye and antibody.

Recommended Assay Procedures

For optimal and reproducible results, BD Horizon Brilliant Stain Buffer should be used anytime two or more BD Horizon Brilliant dyes (including BD OptiBuild Brilliant reagents) are used in the same experiment.  Fluorescent dye interactions may cause staining artifacts which may affect data interpretation.  The BD Horizon Brilliant Stain Buffer was designed to minimize these interactions.  More information can be found in the Technical Data Sheet of the BD Horizon Brilliant Stain Buffer (Cat. No. 563794).

Product Notices

  1. This antibody was developed for use in flow cytometry.
  2. The production process underwent stringent testing and validation to assure that it generates a high-quality conjugate with consistent performance and specific binding activity. However, verification testing has not been performed on all conjugate lots.
  3. Researchers should determine the optimal concentration of this reagent for their individual applications.
  4. An isotype control should be used at the same concentration as the antibody of interest.
  5. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  6. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
  7. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
  8. BD Horizon Brilliant Stain Buffer is covered by one or more of the following US patents: 8,110,673; 8,158,444; 8,575,303; 8,354,239.
  9. BD Horizon Brilliant Ultraviolet 661 is covered by one or more of the following US patents: 8,110,673; 8,158,444; 8,227,187; 8,575,303; 8,354,239.
750108 Rev. 4
Antibody Details
Down Arrow Up Arrow
174031

The 174031 monoclonal antibody specifically recognizes CD354 which is also known as Triggering receptor expressed on myeloid cells 1 (TREM-1) or Triggering receptor expressed on monocytes 1. CD354 (TREM-1) is a ~30 kDa single-pass type I transmembrane glycoprotein that is encoded by Trem1 which belongs to the V-set domain containing family within the Ig superfamily. CD354 (TREM-1) can associate with DAP12, an adaptor protein that contains an immunoreceptor tyrosine-based activation motif (ITAM), to deliver an activating signal intracellularly. It is expressed on neutrophils and some monocytes and macrophages with upregulated expression triggered in response to bacterial lipopolysaccharide (LPS) exposure. CD354 (TREM-1) appears to play important roles in inflammation and septic shock by inducing the production of pro-inflammatory cytokines and chemokines including TNF and MCP-1/CCL2. A soluble form of TREM-1 may be released by cells and serve as an inhibitor of cell surface TREM-1 function.

The antibody was conjugated to BD Horizon™ BUV661 which is part of the BD Horizon Brilliant™ Ultraviolet family of dyes. This dye is a tandem fluorochrome of BD Horizon BUV395 with an Ex Max of 348-nm and an acceptor dye with an Em Max at 661-nm. BD Horizon Brilliant BUV661 can be excited by the ultraviolet laser (355 nm) and detected with a 670/25 filter and a 630 nm LP.  Due to cross laser excitation of this dye, there may be significant spillover into channels detecting APC-like emissions (eg, 670/25-nm filter).

    

Due to spectral differences between labeled cells and beads, using BD™ CompBeads can result in incorrect spillover values when used with BD Horizon BUV661 reagents. Therefore, the use of BD CompBeads or BD CompBeads Plus to determine spillover values for these reagents is not recommended. Different BUV661 reagents (eg, CD4 vs. CD45) can have slightly different fluorescence spillover therefore, it may also be necessary to use clone-specific compensation controls when using these reagents.

750108 Rev. 4
Format Details
Down Arrow Up Arrow
BUV661
The BD Horizon Brilliant™ Ultraviolet 661 (BUV661) Dye is part of the BD Horizon Brilliant™ Ultraviolet family of dyes. This tandem fluorochrome is comprised of a BUV395 donor with an excitation maximum (Ex Max) of 350-nm and an acceptor dye with an emission maximum (Em Max) at 660-nm. BUV661, driven by BD innovation, is designed to be excited by the ultraviolet laser (355-nm) and detected using an optical filter centered near 660-nm (e.g., 670/25 bandpass filter). The acceptor dye can be excited by the Red (628–640-nm) laser resulting in cross-laser excitation and fluorescence spillover. Please ensure that your instrument’s configurations (lasers and optical filters) are appropriate for this dye.
BUV661
Ultraviolet 355 nm
350 nm
660 nm
750108 Rev.4
Citations & References
Down Arrow Up Arrow

Development References (3)

  1. Bouchon A, Dietrich J, Colonna M. Cutting edge: inflammatory responses can be triggered by TREM-1, a novel receptor expressed on neutrophils and monocytes. J Immunol. 2000; 164(10):4991-4995. (Biology). View Reference
  2. Gibot S, Massin F, Marcou M, et al. TREM-1 promotes survival during septic shock in mice.. Eur J Immunol. 2007; 37(2):456-66. (Clone-specific: Flow cytometry). View Reference
  3. Yuan Z, Syed MA, Panchal D, et al. Triggering receptor expressed on myeloid cells 1 (TREM-1)-mediated Bcl-2 induction prolongs macrophage survival.. J Biol Chem. 2014; 289(21):15118-29. (Clone-specific: Flow cytometry). View Reference
750108 Rev. 4

Please refer to Support Documents for Quality Certificates


Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described


Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.