BUV496 Mouse Anti-Human CMRF-56
Product Details
Down Arrow Up Arrow


BD OptiBuild™
CMRF-56 antigen
Human (Tested in Development)
Mouse IgG1, κ
Flow cytometry (Qualified)
0.2 mg/ml
AB_2874116
Aqueous buffered solution containing ≤0.09% sodium azide.
RUO


Preparation And Storage

Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze. The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated with BD Horizon BUV496 under optimal conditions that minimize unconjugated dye and antibody.

Recommended Assay Procedures

For optimal and reproducible results, BD Horizon Brilliant Stain Buffer should be used anytime two or more BD Horizon Brilliant dyes (including BD OptiBuild Brilliant reagents) are used in the same experiment.  Fluorescent dye interactions may cause staining artifacts which may affect data interpretation.  The BD Horizon Brilliant Stain Buffer was designed to minimize these interactions.  More information can be found in the Technical Data Sheet of the BD Horizon Brilliant Stain Buffer (Cat. No. 563794).

Product Notices

  1. This antibody was developed for use in flow cytometry.
  2. The production process underwent stringent testing and validation to assure that it generates a high-quality conjugate with consistent performance and specific binding activity. However, verification testing has not been performed on all conjugate lots.
  3. Researchers should determine the optimal concentration of this reagent for their individual applications.
  4. An isotype control should be used at the same concentration as the antibody of interest.
  5. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  6. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
  7. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
  8. BD Horizon Brilliant Stain Buffer is covered by one or more of the following US patents: 8,110,673; 8,158,444; 8,575,303; 8,354,239.
  9. BD Horizon Brilliant Ultraviolet 496 is covered by one or more of the following US patents: 8,110,673; 8,158,444; 8,227,187; 8,575,303; 8,354,239.
749876 Rev. 4
Antibody Details
Down Arrow Up Arrow
CMRF-56

The CMRF-56 monoclonal antibody specifically binds to a 96 kDa, early activation/differentiation antigen expressed on dendritic cells (DCs). The CMRF-56 antigen is expressed on isolated Langerhans cells, dermal DCs, migratory dermal DCs and monocyte derived DCs (GM-CSF, IL-4, TNF-α). Circulating blood DCs are CMRF-56-, but its expression is induced within 6 hrs of in vitro culture. Tonsil and synovial fluid DCs upregulate CMRF-56 expression following short-term in vitro culture. It is not detected on resting peripheral blood leukocytes, but is on a subpopulation of tonsil B cells and on in vitro cultured CD19+ cells. CMRF-56 was generated using the Hodgkin's-derived L428 cell line as immunogen. This reagent could be useful in flow cytometric or immunomagnetic separation procedures and immunohistochemical staining of acetone-fixed frozen tissue sections.

The antibody was conjugated to BD Horizon™ BUV496 which is part of the BD Horizon Brilliant™ Ultraviolet family of dyes. This dye is a tandem fluorochrome of BD Horizon BUV395 with an Ex Max of 348-nm and an acceptor dye with an Em Max at 496-nm. BD Horizon BUV496 can be excited by the ultraviolet laser (355 nm) and detected with a 515/30 nm filter with a 450LP. Due to the excitation of the acceptor dye by other laser lines, there may be significant spillover into the channel detecting BD Horizon V500 or BV510 (eg, 525/40-nm filter). However, the spillover can be corrected through compensation as with any other dye combination.

749876 Rev. 4
Format Details
Down Arrow Up Arrow
BUV496
The BD Horizon Brilliant™ Ultraviolet 496 (BUV496) Dye is part of the BD Horizon Brilliant™ Ultraviolet family of dyes. This tandem fluorochrome is comprised of a BUV395 donor with an excitation maximum (Ex Max) of 350-nm and an acceptor dye with an emission maximum (Em Max) at 496-nm. BUV496, driven by BD innovation, is designed to be excited by the ultraviolet laser (355-nm) and detected using an optical filter centered near 500-nm (e.g., 515/30-nm bandpass filter). The acceptor dye can be excited by the Violet (405-nm) laser resulting in cross-laser excitation and fluorescence spillover. Please ensure that your instrument’s configurations (lasers and optical filters) are appropriate for this dye.
altImg
BUV496
Ultraviolet 355 nm
350 nm
496 nm
749876 Rev.4
Citations & References
Down Arrow Up Arrow

Development References (3)

  1. Fearnley DB, McLellan AD, Mannering SI, Hock BD, Hart DN. Isolation of human blood dendritic cells using the CMRF-44 monoclonal antibody: implications for studies on antigen-presenting cell function and immunotherapy. Blood. 1997; 89(10):3708-3716. (Clone-specific: Flow cytometry, Immunohistochemistry). View Reference
  2. Hock BD, Fearnley DB, Boyce A. Human dendritic cells express a 95 kDa activation/differentiation antigen defined by CMRF-56. Tissue Antigens. 1999; 53(4 Pt 1):320-334. (Clone-specific: Flow cytometry, Immunohistochemistry). View Reference
  3. Hock BD, Starling GC, Daniel PB, Hart DN. Characterization of CMRF-44, a novel monoclonal antibody to an activation antigen expressed by the allostimulatory cells within peripheral blood, including dendritic cells. Immunology. 1994; 83(4):573-581. (Clone-specific: Flow cytometry, Immunohistochemistry). View Reference
749876 Rev. 4

Please refer to Support Documents for Quality Certificates


Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described


Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.