Skip to main content Skip to navigation
BV650 Mouse Anti-Human CD85g (ILT7)
Product Details
Down Arrow Up Arrow


BD OptiBuild™
LILRA4; CD85g; ILT7; ILT-7; Immunoglobulin-like transcript 7
Human (Tested in Development)
Mouse IgG1, κ
ILT7–FcεRIγ-transfected 2B4 cells
Flow cytometry (Qualified)
0.2 mg/ml
23547
AB_2871507
Aqueous buffered solution containing ≤0.09% sodium azide.
RUO


Preparation And Storage

Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze. The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated with BD Horizon BV650 under optimal conditions that minimize unconjugated dye and antibody.

Recommended Assay Procedures

For optimal and reproducible results, BD Horizon Brilliant Stain Buffer should be used anytime two or more BD Horizon Brilliant dyes (including BD OptiBuild Brilliant reagents) are used in the same experiment.  Fluorescent dye interactions may cause staining artifacts which may affect data interpretation.  The BD Horizon Brilliant Stain Buffer was designed to minimize these interactions.  More information can be found in the Technical Data Sheet of the BD Horizon Brilliant Stain Buffer (Cat. No. 563794).

Product Notices

  1. This antibody was developed for use in flow cytometry.
  2. The production process underwent stringent testing and validation to assure that it generates a high-quality conjugate with consistent performance and specific binding activity. However, verification testing has not been performed on all conjugate lots.
  3. Researchers should determine the optimal concentration of this reagent for their individual applications.
  4. An isotype control should be used at the same concentration as the antibody of interest.
  5. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  6. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
  7. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
  8. BD Horizon Brilliant Stain Buffer is covered by one or more of the following US patents: 8,110,673; 8,158,444; 8,575,303; 8,354,239.
  9. BD Horizon Brilliant Violet 650 is covered by one or more of the following US patents: 8,110,673; 8,158,444; 8,227,187; 8,455,613; 8,575,303; 8,354,239.
  10. Alexa Fluor® is a registered trademark of Life Technologies Corporation.
743351 Rev. 1
Antibody Details
Down Arrow Up Arrow
17G10.2

The 17G10.2 monoclonal antibody specifically binds to human Immunoglobulin Like Transcript 7 (ILT7), also known as CD85g. The ILT7 protein is encoded by the LILRA4 (Leukocyte Immunoglobulin Like Receptor subfamily A member 4) gene. ILT7 is a member of immunoglobulin-like transcripts (ILT) or leukocyte immunoglobulin-like receptor (LIR) gene family. ILT7 is selectively expressed on plasmacytoid dendrtic cells (pDC) but not on myeloid dendritic cells or other peripheral blood leukocytes. In response to IL-3, IL-3 receptor complex signaling downregulates ILT7 expression by pDC. ILT7 associates with the FcεRIγ signal adapter protein to form a receptor complex that can signal through activation of an immunoreceptor-based tyrosine activation motif (ITAM)-mediated signaling pathway. Signaling through the ILT7-FcεRIγ receptor complex negatively regulates the innate immune functions of pDC. ILT7 crosslinking inhibits TLR responses by pDC such as the stimulated production of type I interferon and other cytokines. Bone marrow stromal cell antigen 2 (BST2) has been identified as a biological ligand for ILT7.

The antibody was conjugated to BD Horizon™ BV650 which is part of the BD Horizon Brilliant™ Violet family of dyes. This dye is a tandem fluorochrome of BD Horizon BV421 with an Ex Max of 405-nm and an acceptor dye with an Em Max at 650-nm.  BD Horizon BV650 can be excited by the violet laser and detected in a filter used to detect APC-like dyes (eg, 660/20-nm filter).  Due to the excitation and emission characteristics of the acceptor dye, there will be  spillover into the APC and Alexa Fluor® 700 detectors.  However, the spillover can be corrected through compensation as with any other dye combination.

743351 Rev. 1
Format Details
Down Arrow Up Arrow
BV650
The BD Horizon Brilliant Violet™ 650 (BV650) Dye is part of the BD Horizon Brilliant Violet™ family of dyes. This tandem fluorochrome is comprised of a BV421 donor with an excitation maximum (Ex Max) of 406-nm and an acceptor dye with an emission maximum (Em Max) at 649-nm. BV650, driven by BD innovation, is designed to be excited by the violet laser (405-nm) and detected using an optical filter centered near 650-nm (e.g., a 660/20-nm bandpass filter). The acceptor dye can be excited by the Red (628–640-nm) laser resulting in cross-laser excitation and fluorescence spillover. Please ensure that your instrument’s configurations (lasers and optical filters) are appropriate for this dye.
altImg
BV650
Violet 405 nm
406 nm
649 nm
743351 Rev.1
Citations & References
Down Arrow Up Arrow

Development References (3)

  1. Cao W, Bover L, Cho M, et al. Regulation of TLR7/9 responses in plasmacytoid dendritic cells by BST2 and ILT7 receptor interaction.. J Exp Med. 2009; 206(7):1603-14. (Clone-specific: Activation, Calcium Flux, Flow cytometry, Inhibition). View Reference
  2. Cao W, Bover L. Signaling and ligand interaction of ILT7: receptor-mediated regulatory mechanisms for plasmacytoid dendritic cells. Immunol Rev. 2010; 234(1):163-176. (Clone-specific: Inhibition). View Reference
  3. Cao W, Rosen DB, Ito T, et al. Plasmacytoid dendritic cell-specific receptor ILT7-Fc epsilonRI gamma inhibits Toll-like receptor-induced interferon production.. J Exp Med. 2006; 203(6):1399-405. (Immunogen: Activation, Calcium Flux, Flow cytometry, Functional assay, Inhibition). View Reference
743351 Rev. 1

Please refer to Support Documents for Quality Certificates


Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described


Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.