PE Hamster Anti-Mouse CD3e
Alert icon
Consider BD Horizon RealYellow™ 586 (RY586) Reagents, a bright and clean fluorochrome alternative to PE off the yellow-green laser. RY586 can be used alongside PE on spectral cytometers. More Info #
PE Hamster Anti-Mouse CD3e
CD3e expression in spleen and thymus. BALB/c splenocytes were simultaneously stained with FITC-conjugated anti-mouse CD4 mAb RM4-5 (Cat. No. 553046/553047, left panels), FITC-conjugated anti-mouse CD8a mAb 53-6.7 (Cat. No. 553030/553031, left panels), and PE-conjugated mAb 500A2 (bottom left panel). BALB/c thymocytes were stained with PE-conjugated 500A2 (bottom right panel) or unstained (top right panel). Flow cytometry was performed on a BD FACScan™ flow cytometry system.
CD3e expression in spleen and thymus. BALB/c splenocytes were simultaneously stained with FITC-conjugated anti-mouse CD4 mAb RM4-5 (Cat. No. 553046/553047, left panels), FITC-conjugated anti-mouse CD8a mAb 53-6.7 (Cat. No. 553030/553031, left panels), and PE-conjugated mAb 500A2 (bottom left panel). BALB/c thymocytes were stained with PE-conjugated 500A2 (bottom right panel) or unstained (top right panel). Flow cytometry was performed on a BD FACScan™ flow cytometry system.
Product Details
Down Arrow Up Arrow


BD Pharmingen™
CD3; CD3 epsilon; Cd3e; CD3ε; T3e
Mouse (QC Testing)
Syrian Hamster IgG2, κ
Mouse T-cell receptor
Flow cytometry (Routinely Tested)
0.2 mg/ml
12501
AB_394729
Aqueous buffered solution containing ≤0.09% sodium azide.
RUO


Preparation And Storage

The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated with R-PE under optimum conditions, and unconjugated antibody and free PE were removed. Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze.

Recommended Assay Procedures

It has been observed that pre-incubation of thymus cell suspensions at 37°C for 2 to 4 hours prior to staining enhances the ability of anti-CD3e and anti-αβ TCR mAbs to detect the T-cell receptor on immature thymocytes.

Product Notices

  1. Since applications vary, each investigator should titrate the reagent to obtain optimal results.
  2. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
  3. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
  4. Although hamster immunoglobulin isotypes have not been well defined, BD Biosciences Pharmingen has grouped Armenian and Syrian hamster IgG monoclonal antibodies according to their reactivity with a panel of mouse anti-hamster IgG mAbs. A table of the hamster IgG groups, Reactivity of Mouse Anti-Hamster Ig mAbs, may be viewed at http://www.bdbiosciences.com/documents/hamster_chart_11x17.pdf.
  5. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
553240 Rev. 11
Antibody Details
Down Arrow Up Arrow
500A2

The 500A2 monoclonal antibody specifically binds to the 25-kDa ε chain of the T-cell receptor-associated CD3 complex expressed on mouse thymocytes, mature T lymphocytes, and NKT cells. Plate-bound and soluble forms of the 500A2 antibody can activate T cells in vitro. Activation of a mouse T-cell clone by the 500A2 antibody can be blocked by Fab fragments of the GK1.5 anti-CD4 antibody. This suggests that the 500A2 antibody may bind an epitope on CD3e close to a site at which CD4 associates with the T-cell receptor. The 500A2 antibody reportedly does not to crossreact with rat leukocytes.

This antibody is routinely tested by flow cytometric analysis. Other applications were tested at BD Biosciences Pharmingen during antibody development only or reported in the literature.

553240 Rev. 11
Format Details
Down Arrow Up Arrow
PE
R-Phycoerythrin (PE), is part of the BD family of Phycobiliprotein dyes. This fluorochrome is a multimeric fluorescent phycobiliprotein with excitation maximum (Ex Max) of 496 nm and 566 nm and an emission maximum (Em Max) at 576 nm. PE is designed to be excited by the Blue (488 nm), Green (532 nm) and Yellow-Green (561 nm) lasers and detected using an optical filter centered near 575 nm (e.g., a 575/26-nm bandpass filter). As PE is excited by multiple lasers, this can result in cross-laser excitation and fluorescence spillover on instruments with various combinations of Blue, Green, and Yellow-Green lasers. Please ensure that your instrument’s configurations (lasers and optical filters) are appropriate for this dye.
altImg
PE
Yellow-Green 488 nm, 532 nm, 561 nm
496 nm, 566 nm
576 nm
553240 Rev.11
Citations & References
Down Arrow Up Arrow

Development References (5)

  1. Allison JP, Havran WL, Poenie M, et al. Expression and function of CD3 on murine thymocytes. In: Kappler J, Davis M, ed. The T-Cell Receptor, UCLA Symposia, 73rd Edition. Los Angeles: 1988:33-45.
  2. Havran WL, Poenie M, Kimura J, Tsien R, Weiss A, Allison JP. Expression and function of the CD3-antigen receptor on murine CD4+8+ thymocytes. Nature. 1987; 330(6144):170-173. (Biology). View Reference
  3. Kubo RT, Born W, Kappler JW, Marrack P, Pigeon M. Characterization of a monoclonal antibody which detects all murine alpha beta T cell receptors. J Immunol. 1989; 142(8):2736-2742. (Methodology). View Reference
  4. Ortaldo JR, Winkler-Pickett R, Mason AT, Mason LH. The Ly-49 family: regulation of cytotoxicity and cytokine production in murine CD3+ cells. J Immunol. 1998; 160(1):1158-1165. (Biology). View Reference
  5. Portoles P, Rojo J, Golby A, et al . Monoclonal antibodies to murine CD3 epsilon define distinct epitopes, one of which may interact with CD4 during T cell activation. J Immunol. 1989; 142(12):4169-4175. (Biology). View Reference
View All (5) View Less
553240 Rev. 11

Please refer to Support Documents for Quality Certificates


Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described


Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.