BD ONEFLOW

BD OneFlow ALOT

BD OneFlow™ ALOT Acquisition Template
BD OneFlow™ ALOT Acquisition Template
Sequence of pre-defined dot plots and gates for the analysis of specimens stained with the 8-color BD OneFlow™ ALOT single-test reagent, acquired on BD FACSCanto™ II instrument with BD FACSDiva™ v 8.0.1 software.
BD OneFlow™ ALOT Analysis Template
BD OneFlow™ ALOT Analysis Template
Sequence of pre-defined dot plots and gates for the analysis of sample stained with the 8-color BD OneFlow™ ALOT single-test reagent, acquired on BD FACSCanto™ II instrument with BD FACSDiva™ v 8.0.1 software for the identification of aberrant immature lymphoid and non-lymphoid populations.

 

BD OneFlow LST

BD OneFlow™ LST Acquisition Template (v2.0)
BD OneFlow LST Acquisition Template (v2.0)
Sequence of pre-defined dot plots and gates for the acquisition of sample stained with the 8-color 12-antibody single-test tube BD OneFlow™ LST acquired on a BD FACSCanto™ II flow cytometer with BD FACSDiva™ v 8.0.1 software.
BD OneFlow™ LST Analysis Template (v2.0)
BD OneFlow LST Analysis Template (v2.0)
Sequence of pre-defined dot plots and gates for the analysis of sample stained with the 8-color 12-antibody single-test tube BD OneFlow LST acquired on a BD FACSCanto™ II flow cytometer with BD FACSDiva™ v 8.0.1 software for the identification of normal and aberrant mature lymphocyte populations of B, T and NK cell lineages.

 

BD OneFlow B-CLPD T1

BD OneFlow™ B-CLPD T1 Acquisition Template
BD OneFlow B-CLPD T1 Acquisition Template
Sequence of pre-defined dot plots and gates for the acquisition of peripheral blood and/or bone marrow specimens stained with the 8-color 8-antibody BD OneFlow B-CLPD T1 single-test reagent, acquired on a BD FACSCanto™ II flow cytometer with BD FACSDiva™ v 8.0.1 software.
BD OneFlow™ B-CLPD T1 Analysis Template
BD OneFlow B-CLPD T1 Analysis Template
Sequence of pre-defined dot plots and gates for the analysis of peripheral blood and/or bone marrow specimens stained with the 8-color 8-antibody BD OneFlow B-CLPD T1 single-test reagent, acquired on a BD FACSCanto™ II flow cytometer with BD FACSDiva™ v 8.0.1 software.

 

BD OneFlow PCST

BD OneFlow™ PCST Acquisition Template
BD OneFlow™ PCST Acquisition Template
Sequence of pre-defined dot plots and gates for the acquisition of bone marrow specimen stained with the 8-color 8-antibodies BD OneFlow™ PCST single-test reagent, acquired on BD FACSCanto™ II with BD FACSDiva™ v 8.0.1.
BD OneFlow™ PCST Analysis Template
BD OneFlow™ PCST Analysis Template
Sequence of pre-defined dot plots and gates for the analysis of bone marrow specimen stained with the 8-color 8-antibodies BD OneFlow™ PCST single-test reagent, acquired on BD FACSCanto™ II with BD FACSDiva™ v 8.0.1 for the identification of normal polyclonal and aberrant plasma cell populations.

 

BD OneFlow PCD

BD OneFlow™ PCD Acquisition Template
BD OneFlow™ PCD Acquisition Template
Sequence of pre-defined dot plots and gates for the acquisition of bone marrow specimen stained with the 8-color 8-antibodies single-test tube BD OneFlow™ PCD , acquired on BD FACSCanto™ II with BD FACSDiva™ v 8.0.1.
BD OneFlow™ PCD Analysis Template
BD OneFlow™ PCD Analysis Template
Sequence of pre-defined dot plots and gates for the analysis of bone marrow specimen stained with the 8-color 8-antibodies single-test tube BD OneFlow™ PCD , acquired on BD FACSCanto™ II with BD FACSDiva™ v 8.0.1 for further investigation of plasma cell populations after or in combination with the use of the BD OneFlow PCST tube.

 

Instrument Setup

BD OneFlow™ Setup Template
BD OneFlow™ Setup Template
BD OneFlow™ Setup Beads are used on a BD FACSCanto™ II with BD FACSDiva™ v 8.0.1 to adjust the beads’ Mean Fluorescent Intensity (MFI) in each detector for instrument standardization.