BD BioCoat™ Tumor Invasion System

BD BioCoat™ Tumor Invasion System

Evaluate and quantitate endothelial cell invasion using real-time fluorescence and non-destructive sample preparation.

BD BioCoat™ Tumor Invasion Systems provide cells with conditions that allow assessment of their invasive potential in vitro. Available as a 24-Multiwell insert plate containing the patented BD FluoroBlok™ PET membrane (8.0 µm pore size) uniformly coated with BD Matrigel™ Matrix which serves as an authentic reconstituted basement membrane in vitro. This provides a true barrier to non-invasive cells while presenting an appropriate protein structure for invading cells to penetrate the BD Matrigel Matrix and pass through the FluoroBlok membrane. Only those cells that appear on the underside of the FluoroBlok membrane are quantitated in real time by fluorescence, providing a signal that can be directly correlated to cell number. All 24 inserts are part of a single unit. These proprietary systems are compatible with most fluorescent plate readers, robots and fluid handlers.

Offers:

  • Assay precision: CV 15% observed
  • Highly reproducible results average: Average Z' = 0.7
  • Easy-to-use: No need for multiple pipeting or handling steps. Just add cells, label, and read.
  • Robust platform with high signal-to-noise.

Run Real-Time Tumor Cell Invasion Assays Without Destroying Your Samples

HT-1080 or 3T3 cells labeled with the fluorescent dye DiI were placed in a BD BioCoat™ Tumor Invasion System in the presence of chemoattractant (5% Fetal Bovine Serum). Invasion was measured by detecting the fluorescence of cells invading through the BD Matrigel Matrix and the pores of the FluoroBlok membrane with an Applied Biosystems CytoFluor® 4000 plate reader at 530 nm excitation and 590 nm emission (bottom-reading mode).

Assay-to-Assay Reproducibility

A single lot of BD BioCoat™ Tumor Invasion Systems was assayed four times at three and four day intervals. The data is normalized to a migration control to minimize variability due to cell preparation and/or fluorescent dye uptake. The inter-assay means for the invasive HT-1080 cells was 4837±602 FU (CV = 12.5%).

Technical Documents

  • BD BioCoat™ Tumor Invasion System--Product Sheet [ PDF ]
  • BD BioCoat™ Tumor Invasion System--Guidelines for Use [ PDF ]

The following Technical Notes is available for download or by calling
Technical Services at 800.343.2035

Note No. Title
436 Set Up Guidelines and Dimensional Templates for Fluorescence Plate Readers Used With BD Falcon™ HTS FluoroBlok™ Insert Systems and BD BioCoat™ Multiwell Insert Cell-Based Assays

Ordering Information

Catalog Number Description Quantity / Pack
BD BioCoat™ FluoroBlok™ Invasion Systems
354165 BD BioCoat™ Tumor Invasion System 1
354166 BD BioCoat™ Tumor Invasion System 5
Please contact Technical Service at 800.343.2035 for more information on our line of BD Falcon FluoroBlok Inserts and BD BioCoat FluoroBlok Invasion Systems. Our highly trained technical service staff will assist you in determining which product is best for your cell type and application. Let us put our comprehensive technical database and expertise in cell culture to work for you.